DT-IO1300 Laboratory pH/Ion meter
High precision laboratory pH/ion?meter, with optional 5 ion concentration measurement methods. The setting menu can customize 20 functional parameters. The instrument is suitable for measuring the pH, reduction-oxidation potential (ORP), ion concentration and water hardness value of the sample, with the measurement accuracy: 0.002pH.
pH mode characteristics:
? High precision laboratory pH/ion?meter with 7-inch TFT display.
? 1 to 5 points calibration, automatic recognition of USA, NIST, DIN standard buffer solution.
? Solution temperature coefficient, compensates for pure water measurements and converts the readings to 25°C.
ORP mode characteristics:
? 1 point offset calibration, allows adjusting display values to known standards.
? Relative and absolute mV mode, ensures reliable ORP measurement.
Ion concentration mode characteristics:
? 2 to 5 points calibration, including 8 optional concentration calibration points.
? Electrode management, can store and invoke up to 3 electrode slopes.
? Optional measurement methods - direct reading, known addition, known decrement, sample addition, sample decrement; Unit of concentration - ppm, mg/L, mol/L, mmol/L.
Water hardness mode characteristics:
? 2 to 5 point calibration from low to high concentration.
? Optional water hardness units - German degree (°dH), British degree (°e), French degree (°fH), mg/L and mmol/L.
Common characteristics:
? Automatic temperature compensation, ensures accurate measurement over the full range.
? Automatic end-point locking, retains stable readings for easy browsing and recording.
? Timed interval reading, sending measurement data to memory or printer.
? Limit alarm, automatically warns whether the measured value exceeds the set range.
? Calibration expiration reminder, prompts users to calibrate the instrument regularly.
? Calibration report, showing date, time, calibration point and slope.
? Password protection, preventing from unauthorized calibration and setting.
? Expanding memory, stores or accesses up to 1000 groups of data.
? Reset function, automatically restores the meter to factory default settings.
pH | ------------------------------------------------------------------------------------ |
---|---|
Measuring range | -2.000~20.000pH |
Display resolution | 0.001/0.01pH, optional |
Measurement accuracy | ±0.002pH |
Calibration point | 1 to 5 points |
pH buffer option | USA/NIST/DIN/5 kinds of custom buffer solution |
ORP | ------------------------------------------------------------------------------------ |
Measuring range | ±2000.0mV |
Display resolution | 0.1 mV |
Calibration point | ±0.2mV |
Measurement accuracy | 1 point |
Measurement mode | Relative or absolute mV |
Ion concentration | ------------------------------------------------------------------------------------ |
Measuring range | 0.001~30000 (subject to the range of ion-selective electrode) |
Display resolution | 0.001, 0.01, 0.1, 1, automatic |
Measurement accuracy | ±0.5% F.S. (monovalent ion), ±1% F.S. (divalent ion) |
Calibration point | 2 to 5 points |
Calibration solution | 0.001/0.01/0.1/1/10/100/1000/10000 |
Measuring unit | ppm, mg/L, mol/L, mmol/L |
Measurement method | Direct reading, known addition, known decrement, sample addition, sample decrement |
Water hardness | ------------------------------------------------------------------------------------ |
Measuring range (concentration) | 0.05~200mmol/L |
Measuring range (°dH) | 0~1120°dH |
Measuring range (°e) | 0~1404°e |
Measuring range (°fH) | 0~2000°fH |
Measuring range (Ca??) | 0~8000mg/L |
Measuring range (CaCO?) | 0~19999mg/L |
Measuring range (CaO) | 0~11220mg/L |
Display resolution | 0.001, 0.01, 0.1, 1, automatic |
Measurement accuracy | ±1% F.S. |
Calibration point | 2 to 5 points |
Calibration solution | 0.01/0.1/1/10/100mmol/L |
Temperature | ------------------------------------------------------------------------------------ |
Measuring range | 0~105°C/32~221°F |
Display resolution | 0.1°C/°F |
Measurement accuracy | ±0.5°C/±0.9°F |
Calibration point | 1 point |
Calibration range | Measured value ±10°C/°F |
Other parameters | ------------------------------------------------------------------------------------ |
Temperature Compensation | 0~100°C/32~212°F, manual or automatic |
Stability condition | Standard or high precision |
Measurement mode | Continuous or automatic end locking |
Timed interval reading | 10/30/60 seconds, 10/30 minutes or off |
Calibration expiration reminder | 1 to 31 days or closed |
High/low limit alarm | Optional |
Password protection | Four-digit number |
Data storage | 1000 groups |
Communication output | USB |
Connector | BNC, 3.5mm microphone socket |
Display | 7 inch TFT LCD display |
Power supply | DC 12V power adapter |
Dimensions (LxWxH) | 240 x 220 x 80 mm |
Net weight | 1.7kg |
Includes | One DT-IO1300 host K201-BNC Laboratory pH electrode TP-10K temperature probe pH Standard buffer solution (PH 4.01/7.00/10.01) DC 12V power adapter |